Datasheet

SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
1306
43.7.74 Receive Symbol Errors Register
Name: GMAC_RSE
Address: 0x40034198
Access: Read-only
RXSE: Receive Symbol Errors
This register counts the number of frames that had GRXER asserted during reception. For 10/100 mode symbol errors are
counted regardless of frame length checks. Receive symbol errors will also be counted as an FCS or alignment error if the
frame is between 64 and 1518 bytes (1536 bytes if bit 8 is set in the Network Configuration Register). If the frame is larger
it will be recorded as a jabber error. See Section 43.7.2 “Network Configuration Register”.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
–––––– RXSE
76543210
RXSE