Datasheet

654
11011B–ATARM–21-Feb-12
SAM3N
654
11011B–ATARM–21-Feb-12
SAM3N
Figure 33-3. EOCx and DRDY Flag Behavior
If the ADC_CDR is not read before further incoming data is converted, the corresponding Over-
run Error (OVREx) flag is set in the Overrun Status Register (ADC_OVER).
Likewise, new data converted when DRDY is high sets the GOVRE bit (General Overrun Error)
in ADC_SR.
The OVREx flag is automatically cleared when ADC_OVER is read, and GOVRE flag is auto-
matically cleared when ADC_SR is read.
Read the ADC_CDRx
EOCx
DRDY
Read the ADC_LCDR
CHx
(ADC_CHSR)
(ADC_SR)
(ADC_SR)
Write the ADC_CR
with START = 1
Write the ADC_CR
with START = 1