Datasheet
225
11011B–ATARM–21-Feb-12
SAM3N
225
11011B–ATARM–21-Feb-12
SAM3N
13.5.1 Real-time Timer Mode Register
Register Name: RTT_MR
Address: 0x400E1430
Access Type: Read-write
• RTPRES: Real-time Timer Prescaler Value
Defines the number of SLCK periods required to increment the Real-time timer. RTPRES is defined as follows:
RTPRES = 0: The prescaler period is equal to 2
16
* SCLK period.
RTPRES ≠ 0: The prescaler period is equal to RTPRES * SCLK period.
• ALMIEN: Alarm Interrupt Enable
0 = The bit ALMS in RTT_SR has no effect on interrupt.
1 = The bit ALMS in RTT_SR asserts interrupt.
• RTTINCIEN: Real-time Timer Increment Interrupt Enable
0 = The bit RTTINC in RTT_SR has no effect on interrupt.
1 = The bit RTTINC in RTT_SR asserts interrupt.
• RTTRST: Real-time Timer Restart
0 = No effect.
1 = Reloads and restarts the clock divider with the new programmed value. This also resets the 32-bit counter.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
–––––RTTRSTRTTINCIENALMIEN
15 14 13 12 11 10 9 8
RTPRES
76543210
RTPRES