Datasheet
195
8284D–AVR–6/11
ATmega169A/PA/329A/PA/3290A/PA/649A/P/6490A/P
20.10 Examples of Baud Rate Setting
For standard crystal and resonator frequencies, the most commonly used baud rates for asyn-
chronous operation can be generated by using the UBRRn settings in Table 20-3 on page 193.
UBRRn values which yield an actual baud rate differing less than 0.5% from the target baud
rate, are bold in the table. Higher error ratings are acceptable, but the Receiver will have less
noise resistance when the error ratings are high, especially for large serial frames (see ”Asyn-
chronous Operational Range” on page 192). The error values are calculated using the following
equation:
Error[%]
BaudRate
Closest Match
BaudRate
-------------------------------------------------------- 1–
⎝⎠
⎛⎞
100%•=
Table 20-4. Examples of UBRRn Settings for Commonly Used Oscillator Frequencies
Baud
Rate
(bps)
f
osc
= 1.0000MHz f
osc
= 1.8432MHz f
osc
= 2.0000MHz
U2Xn = 0 U2Xn = 1 U2Xn = 0 U2Xn = 1 U2Xn = 0 U2Xn = 1
UBRRn Error UBRRn Error UBRRn Error UBRRn Error UBRRn Error UBRRn Error
2400 25 0.2% 51 0.2% 47 0.0% 95 0.0% 51 0.2% 103 0.2%
4800 12 0.2% 25 0.2% 23 0.0% 47 0.0% 25 0.2% 51 0.2%
9600 6 -7.0% 12 0.2% 11 0.0% 23 0.0% 12 0.2% 25 0.2%
14.4k 3 8.5% 8 -3.5% 7 0.0% 15 0.0% 8 -3.5% 16 2.1%
19.2k 2 8.5% 6 -7.0% 5 0.0% 11 0.0% 6 -7.0% 12 0.2%
28.8k 1 8.5% 3 8.5% 3 0.0% 7 0.0% 3 8.5% 8 -3.5%
38.4k 1 -18.6% 2 8.5% 2 0.0% 5 0.0% 2 8.5% 6 -7.0%
57.6k 0 8.5% 1 8.5% 1 0.0% 3 0.0% 1 8.5% 3 8.5%
76.8k – – 1 -18.6% 1 -25.0% 2 0.0% 1 -18.6% 2 8.5%
115.2k – – 0 8.5% 0 0.0% 1 0.0% 0 8.5% 1 8.5%
230.4k––––––00.0%––––
250k––––––––––00.0%
Max.
(1)
62.5kbps 125kbps 115.2kbps 230.4kbps 125kbps 250kbps
1. UBRR = 0, Error = 0.0%