Datasheet
123
ATmega323(L)
1457E–11/01
Analog Comparator
Multiplexed Input
It is potor, as shown in Table . If ACME is cleared (zero) or ADEN is set (one), PB3
(AIN1) is applied to the negative input to the Analog Comparator. t
Table 43. Analog Comparator Multiplexed Input
ACME ADEN MUX2..0 Analog Comparator Negative Input
0 x xxx AIN1
1 1 xxx AIN1
1 0 000 ADC0
1 0 001 ADC1
1 0 010 ADC2
1 0 011 ADC3
1 0 100 ADC4
1 0 101 ADC5
1 0 110 ADC6
1 0 111 ADC7