Datasheet

190
8018P–AVR–08/10
ATmega169P
19.10 Examples of Baud Rate Setting
For standard crystal and resonator frequencies, the most commonly used baud rates for asyn-
chronous operation can be generated by using the UBRRn settings in Table 19-4. UBRRn
values which yield an actual baud rate differing less than 0.5% from the target baud rate, are
bold in the table. Higher error ratings are acceptable, but the Receiver will have less noise resis-
tance when the error ratings are high, especially for large serial frames (see ”Asynchronous
Operational Range” on page 186). The error values are calculated using the following equation:
Note: 1. UBRRn = 0, Error = 0%.
Error[%]
BaudRate
Closest Match
BaudRate
-------------------------------------------------------- 1
⎝⎠
⎛⎞
100%=
Table 19-4. Examples of UBRRn Settings for Commonly Used Oscillator Frequencies
Baud
Rate
(bps)
f
osc
= 1.0000 MHz f
osc
= 1.8432 MHz f
osc
= 2.0000 MHz
U2Xn = 0 U2Xn = 1 U2Xn = 0 U2Xn = 1 U2Xn = 0 U2Xn = 1
UBRRn Error UBRRn Error UBRRn Error UBRRn Error UBRRn Error UBRRn Error
2400 25 0.2% 51 0.2% 47 0.0% 95 0.0% 51 0.2% 103 0.2%
4800 12 0.2% 25 0.2% 23 0.0% 47 0.0% 25 0.2% 51 0.2%
9600 6 -7.0% 12 0.2% 11 0.0% 23 0.0% 12 0.2% 25 0.2%
14.4k 3 8.5% 8 -3.5% 7 0.0% 15 0.0% 8 -3.5% 16 2.1%
19.2k 2 8.5% 6 -7.0% 5 0.0% 11 0.0% 6 -7.0% 12 0.2%
28.8k 1 8.5% 3 8.5% 3 0.0% 7 0.0% 3 8.5% 8 -3.5%
38.4k 1 -18.6% 2 8.5% 2 0.0% 5 0.0% 2 8.5% 6 -7.0%
57.6k 0 8.5% 1 8.5% 1 0.0% 3 0.0% 1 8.5% 3 8.5%
76.8k 1 -18.6% 1 -25.0% 2 0.0% 1 -18.6% 2 8.5%
115.2k 0 8.5% 0 0.0% 1 0.0% 0 8.5% 1 8.5%
230.4k––––––00.0%–––
250k–––––––––00.0%
Max.
(1)
62.5 Kbps 125 Kbps 115.2 Kbps 230.4 Kbps 125 Kbps 250 Kbps