Datasheet
90E32AS ENHANCED POLY-PHASE HIGH-PERFORMANCE WIDE-SPAN ENERGY METERING IC
Function Description 13 April 2, 2013
3.4 ANALOG/DIGITAL CHANNEL MAPPING
Analog channel to digital channel mapping:
The 6 analog ADC channels can be flexibly mapped to the 6 digital
metering/measuring channels (V/I phase A/B/C). Refer to the Channel-
MapI and ChannelMapU registers for configuration.
Note that channel mapping is only valid in Normal mode and Patial
Measurement mode.
Figure-3 Channel to Phase Mapping
V CH_A
Analog Digital
V CH0
V CH1
V CH2
I CH0
I CH1
I CH2
V CH_B
V CH_C
I CH_A
I CH_B
I CH_C
Flexible Channel mapping