Datasheet
314
AT32UC3A
The receiver samples the RXD line. If the line is sampled during one half of a bit time at 0, a start
bit is detected and data, parity and stop bits are successively sampled on the bit rate clock.
If the oversampling is 16, (OVER at 0), a start is detected at the eighth sample at 0. Then, data
bits, parity bit and stop bit are sampled on each 16 sampling clock cycle. If the oversampling is 8
(OVER at 1), a start bit is detected at the fourth sample at 0. Then, data bits, parity bit and stop
bit are sampled on each 8 sampling clock cycle.
The number of data bits, first bit sent and parity mode are selected by the same fields and bits
as the transmitter, i.e. respectively CHRL, MODE9, MSBF and PAR. For the synchronization
mechanism only, the number of stop bits has no effect on the receiver as it considers only one
stop bit, regardless of the field NBSTOP, so that resynchronization between the receiver and the
transmitter can occur. Moreover, as soon as the stop bit is sampled, the receiver starts looking
for a new start bit so that resynchronization can also be accomplished when the transmitter is
operating with one stop bit.
Figure 26-12 on page 314 and Figure 26-13 on page 314 illustrate start detection and character
reception when USART operates in asynchronous mode.
Figure 26-12. Asynchronous Start Detection
Figure 26-13. Asynchronous Character Reception
Sampling
Clock (x16)
RXD
Start
Detection
Sampling
Baud Rate
Clock
RXD
Start
Rejection
Sampling
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 0 1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
D0
Sampling
D0 D1 D2 D3 D4 D5 D6 D7
RXD
Parity
Bit
Stop
Bit
Example: 8-bit, Parity Enabled
Baud Rate
Clock
Start
Detection
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
32058K