44.9.4 SSC Receive Frame Mode Register
Name: SSC_RFMR
Address: 0xF0010014
Access: Read-write
This register can only be written if the WPEN bit is cleared in “SSC Write Protect Mode Register” .
• DATLEN: Data Length
0 = Forbidden value (1-bit data length not supported).
Any other value: The bit stream contains DATLEN + 1 data bits.
• LOOP: Loop Mode
0 = Normal operating mode.
1 = RD is driven by TD, RF is driven by TF and TK drives RK.
• MSBF: Most Significant Bit First
0 = The lowest significant bit of the data register is sampled first in the bit stream.
1 = The most significant bit of the data register is sampled first in the bit stream.
• DATNB: Data Number per Frame
This field defines the number of data words to be received after each transfer start, which is equal to (DATNB + 1).
• FSLEN: Receive Frame Sync Length
This field defines the number of bits sampled and stored in the Receive Sync Data Register. When this mode is selected by the
START field in the Receive Clock Mode Register, it also determines the length of the sampled data to be compared to the Com-
pare 0 or Compare 1 register.
This field is used with FSLEN_EXT to determine the pulse length of the Receive Frame Sync signal.
Pulse length is equal to FSLEN + (FSLEN_EXT * 16) + 1 Receive Clock periods.
31 30 29 28 27 26 25 24
FSLEN_EXT – – – FSEDGE
23 22 21 20 19 18 17 16
– FSOS FSLEN
15 14 13 12 11 10 9 8
––– – DATNB
765 43210
MSBF – LOOP DATLEN