Datasheet
949
SAM9X35 [DATASHEET]
11055E–ATARM–10-Mar-2014
• TRACKTIM: Tracking Time
Tracking Time = (TRACKTIM + 1) * ADCClock periods.
• USEQ: Use Sequence Enable
5 SUT80 80 periods of ADCClock
6 SUT96 96 periods of ADCClock
7 SUT112 112 periods of ADCClock
8 SUT512 512 periods of ADCClock
9 SUT576 576 periods of ADCClock
10 SUT640 640 periods of ADCClock
11 SUT704 704 periods of ADCClock
12 SUT768 768 periods of ADCClock
13 SUT832 832 periods of ADCClock
14 SUT896 896 periods of ADCClock
15 SUT960 960 periods of ADCClock
Value Name Description
0 NUM_ORDER
Normal Mode: The controller converts channels in a simple numeric order depending only on the
channel index.
1 REG_ORDER
User Sequence Mode: The sequence respects what is defined in ADC_SEQR1 and ADC_SEQR2
registers and can be used to convert several times the same channel.
Value Name Description