41.9.20 CAN Message Data High Register
Name: CAN_MDHx [x=0..7]
Address: 0xF8000218 (0)[0], 0xF8000238 (0)[1], 0xF8000258 (0)[2], 0xF8000278 (0)[3], 0xF8000298 (0)[4],
0xF80002B8 (0)[5], 0xF80002D8 (0)[6], 0xF80002F8 (0)[7], 0xF8004218 (1)[0], 0xF8004238 (1)[1], 0xF8004258
(1)[2], 0xF8004278 (1)[3], 0xF8004298 (1)[4], 0xF80042B8 (1)[5], 0xF80042D8 (1)[6], 0xF80042F8 (1)[7]
Access: Read-write
MDH: Message Data High Value
When MRDY field is set in the CAN_MSRx register, the upper 32 bits of a received message are read or written by the software
application. Otherwise, the MDH value is locked by the CAN controller to send/receive a new message.
In Receive with overwrite, the CAN controller may modify MDH value while the software application reads MDH and MDL regis-
ters. To check that MDH and MDL do not belong to different messages, the application has to check the MMI field in the
CAN_MSRx register. In this mode, the software application must re-read CAN_MDH and CAN_MDL, while the MMI bit in the
CAN_MSRx register is set.
Bytes are received/sent on the bus in the following order:
1. CAN_MDL[7:0]
2. CAN_MDL[15:8]
3. CAN_MDL[23:16]
4. CAN_MDL[31:24]
5. CAN_MDH[7:0]
6. CAN_MDH[15:8]
7. CAN_MDH[23:16]
8. CAN_MDH[31:24]
31 30 29 28 27 26 25 24
MDH
23 22 21 20 19 18 17 16
MDH
15 14 13 12 11 10 9 8
MDH
76543210
MDH