Datasheet

205
SAM9X35 [DATASHEET]
11055E–ATARM–10-Mar-2014
22.13.19 PLL Charge Pump Current Register
Name: PMC_PLLICPR
Address: 0xFFFFFC80
Access: Write-only
ICPLLA: Charge Pump Current
To optimize clock performance, this field must be programmed as specified in “PLL A Characteristics” in the Electrical Character-
istics section of the product datasheet.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
–––––––ICPLLA