Datasheet
781
SAM9X35 [DATASHEET]
11055E–ATARM–10-Mar-2014
Figure 39-23. Timeguard Operations
Table 39-9 indicates the maximum length of a timeguard period that the transmitter can handle in relation to the function
of the Baud Rate.
39.7.3.11 Receiver Time-out
The Receiver Time-out provides support in handling variable-length frames. This feature detects an idle condition on the
RXD line. When a time-out is detected, the bit TIMEOUT in the Channel Status Register (US_CSR) rises and can
generate an interrupt, thus indicating to the driver an end of frame.
The time-out delay period (during which the receiver waits for a new character) is programmed in the TO field of the
Receiver Time-out Register (US_RTOR). If the TO field is programmed to 0, the Receiver Time-out is disabled and no
time-out is detected. The TIMEOUT bit in US_CSR remains to 0. Otherwise, the receiver loads a 16-bit counter with the
value programmed in TO. This counter is decremented at each bit period and reloaded each time a new character is
received. If the counter reaches 0, the TIMEOUT bit in the Status Register rises.
Then, the user can either:
Stop the counter clock until a new character is received. This is performed by writing the Control Register (US_CR)
with the STTTO (Start Time-out) bit to 1. In this case, the idle state on RXD before a new character is received will
not provide a time-out. This prevents having to handle an interrupt before a character is received and allows
waiting for the next idle state on RXD after a frame is received.
Obtain an interrupt while no character is received. This is performed by writing US_CR with the RETTO (Reload
and Start Time-out) bit to 1. If RETTO is performed, the counter starts counting down immediately from the
value TO. This enables generation of a periodic interrupt so that a user time-out can be handled, for example when
no key is pressed on a keyboard.
D0 D1 D2 D3 D4 D5 D6 D7
TXD
Start
Bit
Parity
Bit
Stop
Bit
Baud Rate
Clock
Start
Bit
TG = 4
Write
US_THR
D0 D1 D2 D3 D4 D5 D6 D7
Parity
Bit
Stop
Bit
TXRDY
TXEMPTY
TG = 4
Table 39-9. Maximum Timeguard Length Depending on Baud Rate
Baud Rate Bit time Timeguard
Bit/sec µs ms
1 200 833 212.50
9 600 104 26.56
14400 69.4 17.71
19200 52.1 13.28
28800 34.7 8.85
33400 29.9 7.63
56000 17.9 4.55
57600 17.4 4.43
115200 8.7 2.21