Datasheet
719
SAM9X25 [DATASHEET]
11054E–ATARM–10-Mar-2014
1 = The External Trigger Interrupt is enabled.
36.7.12 TC Block Control Register
Name: TC_BCR
Address: 0xF80080C0 (0), 0xF800C0C0 (1)
Access: Write-only
• SYNC: Synchro Command
0 = No effect.
1 = Asserts the SYNC signal which generates a software trigger simultaneously for each of the channels.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
–––––––SYNC