Datasheet

705
SAM9X25 [DATASHEET]
11054E–ATARM–10-Mar-2014
36.7.2 TC Channel Mode Register: Capture Mode
Name: TC_CMRx [x=0..2] (WAVE = 0)
Address: 0xF8008004 (0)[0], 0xF8008044 (0)[1], 0xF8008084 (0)[2], 0xF800C004 (1)[0], 0xF800C044 (1)[1],
0xF800C084 (1)[2]
Access: Read-write
TCCLKS: Clock Selection
CLKI: Clock Invert
0 = Counter is incremented on rising edge of the clock.
1 = Counter is incremented on falling edge of the clock.
BURST: Burst Signal Selection
LDBSTOP: Counter Clock Stopped with RB Loading
0 = Counter clock is not stopped when RB loading occurs.
1 = Counter clock is stopped when RB loading occurs.
LDBDIS: Counter Clock Disable with RB Loading
0 = Counter clock is not disabled when RB loading occurs.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
LDRB LDRA
15 14 13 12 11 10 9 8
WAVE CPCTRG ABETRG ETRGEDG
76543210
LDBDIS LDBSTOP BURST CLKI TCCLKS
Value Name Description
0 TIMER_CLOCK1 Clock selected: TCLK1
1 TIMER_CLOCK2 Clock selected: TCLK2
2 TIMER_CLOCK3 Clock selected: TCLK3
3 TIMER_CLOCK4 Clock selected: TCLK4
4 TIMER_CLOCK5 Clock selected: TCLK5
5 XC0 Clock selected: XC0
6 XC1 Clock selected: XC1
7 XC2 Clock selected: XC2
Value Name Description
0 NONE The clock is not gated by an external signal.
1 XC0 XC0 is ANDed with the selected clock.
2 XC1 XC1 is ANDed with the selected clock.
3 XC2 XC2 is ANDed with the selected clock.