28.5.9 Error Location Interrupt Status Register
Name: PMERRLOC_ELISR
Address: 0xFFFFE620
Access: Read-only
Reset: 0x00000000
• DONE: Computation Terminated Interrupt Status
• ERR_CNT: Error Counter Value
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––– ERR_CNT
76543210
–––––––DONE