Datasheet

125
SAM9X25 [DATASHEET]
11054E–ATARM–10-Mar-2014
15.6.2 RTC Mode Register
Name: RTC_MR
Address: 0xFFFFFEB4
Access: Read-write
HRMOD: 12-/24-hour Mode
0 = 24-hour mode is selected.
1 = 12-hour mode is selected.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
–––––––HRMOD