Datasheet

Table Of Contents
885
SAM9N12/SAM9CN11/SAM9CN12 [DATASHEET]
11063K–ATARM–05-Nov-13
42.8.1 ADC Control Register
Name: ADC_CR
Address: 0xF804C000
Access: Write-only
SWRST: Software Reset
0: No effect.
1: Resets the ADC simulating a hardware reset.
START: Start Conversion
0: No effect.
1: Begins analog-to-digital conversion.
TSCALIB: Touchscreen Calibration
0: No effect.
1: Programs screen calibration (VDD/GND measurement)
The calibration sequence is performed during the next sequence when command is launched during an already started conver-
sion sequence, or at the start of the second conversion sequence located after the TSCALIB command, if it is launched when no
conversion is in progress (sleep mode, waiting a trigger event).
TSCALIB measurement sequence does not affect the last data converted register (ADC_LDCR).
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
–––––TSCALIBSTARTSWRST