Datasheet
1296
SAM9M10 [DATASHEET]
6355F–ATARM–12-Mar-13
46.11.31 Post Processor Alpha Blending GUI 2 Component Base Address
Name: VDEC_ABGUI2BA
Access: Read-write
• AB_GUI2_BA: Alpha Blending GUI 2 Base Address
Base address for alpha blending input 2 (if mask2 is used in alpha blending mode). Format of data is 24-bit RGB/YCbCr
and endian/swap -mode is as in PP input. Amount of data is informed with mask 2 size.
31 30 29 28 27 26 25 24
AB_GUI2_BA
23 22 21 20 19 18 17 16
AB_GUI2_BA
15 14 13 12 11 10 9 8
AB_GUI2_BA
76543210
AB_GUI1_BA – –