Datasheet
124
SAM9M10 [DATASHEET]
6355F–ATARM–12-Mar-13
17.7.3 Shutdown Status Register
Name: SHDW_SR
Address: 0xFFFFFD18
Access: Read-only
• WAKEUP0: Wake-up 0 Status
0 = No wake-up event occurred on the corresponding wake-up input since the last read of SHDW_SR.
1 = At least one wake-up event occurred on the corresponding wake-up input since the last read of SHDW_SR.
• RTTWK: Real-time Timer Wake-up
0 = No wake-up alarm from the RTT occurred since the last read of SHDW_SR.
1 = At least one wake-up alarm from the RTT occurred since the last read of SHDW_SR.
• RTCWK: Real-time Clock Wake-up
0 = No wake-up alarm from the RTC occurred since the last read of SHDW_SR.
1 = At least one wake-up alarm from the RTC occurred since the last read of SHDW_SR.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––RTCWKRTTWK
15 14 13 12 11 10 9 8
––––––––
76543210
–––––––WAKEUP0