Datasheet

457
SAM9G25 [DATASHEET]
11032D–ATARM–10-Mar-2014
Figure 30-25.Anticipate Precharge/Active Command in Bank 2 during Read Access in Bank 1
NOP READ NOP
0
NOPPRECH ACT READ
1
1
2
Anticipate command, Precharge/Active Bank 2
Trp
Read access in Bank 1
SDClK
A[12:0]
COMMAND
BA[1:0]
DQS[1:0]
Da
Db
Dc
Dd De Df Dg Dh
Di Dj Dk Dl
D[15:0]
3
DM1:0]