Datasheet

303
SAM9G25 [DATASHEET]
11032D–ATARM–10-Mar-2014
24.6.8 Debug Unit Transmit Holding Register
Name: DBGU_THR
Address: 0xFFFFF21C
Access: Write-only
TXCHR: Character to be Transmitted
Next character to be transmitted after the current character if TXRDY is not set.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
TXCHR