Datasheet

136
SAM9G25 [DATASHEET]
11032C–ATARM–25-Jan-13
15.6.6 RTC Calendar Alarm Register
Name: RTC_CALALR
Address: 0xFFFFFEC4
Access: Read-write
MONTH: Month Alarm
This field is the alarm field corresponding to the BCD-coded month counter.
MTHEN: Month Alarm Enable
0 = The month-matching alarm is disabled.
1 = The month-matching alarm is enabled.
•DATE: Date Alarm
This field is the alarm field corresponding to the BCD-coded date counter.
DATEEN: Date Alarm Enable
0 = The date-matching alarm is disabled.
1 = The date-matching alarm is enabled.
31 30 29 28 27 26 25 24
DATEEN DATE
23 22 21 20 19 18 17 16
MTHEN –– MONTH
15 14 13 12 11 10 9 8
––––––––
76543210
––––––––