Datasheet

1052
SAM9G25 [DATASHEET]
11032C–ATARM25-Jan-13
46.11.2 Static Power Consumption
Note: 1. If cable is connected add 200 µA (Typical) due to Pull-up/Pull-down current consumption.
46.11.3 Dynamic Power Consumption
Note: 1. Including 1mA due to Pull-up/Pull-down current consumption.
Table 46-20. Static Power Consumption
Symbol Parameter Conditions Min Typ Max Unit
I
BIAS
Bias current consumption on
VBG
A
I
VDDUTMII
HS Transceiver and I/O current
consumption
A
LS / FS Transceiver and I/O
current consumption
no connection(1) 3 µA
I
VDDUTMIC
Core, PLL, and Oscillator
current consumption
2 µA
Table 46-21. Dynamic Power Consumption
Symbol Parameter Conditions Min Typ Max Unit
I
BIAS
Bias current consumption on
VBG
0.7 0.8 mA
I
VDDUTMII
HS Transceiver current
consumption
HS transmission 47 60 mA
HS Transceiver current
consumption
HS reception 18 27 mA
LS / FS Transceiver current
consumption
FS transmission 0m cable(1) 4 6 mA
LS / FS Transceiver current
consumption
FS transmission 5m cable(1) 26 30 mA
LS / FS Transceiver current
consumption
FS reception(1) 3 4.5 mA
I
VDDUTMIC
PLL, Core and Oscillator current
consumption
5.5 9 mA