Datasheet

1037
SAM9G25 [DATASHEET]
11032C–ATARM–25-Jan-13
45.6.26.15 Receive Symbol Errors Register
Name: EMAC_RSE
Address: 0xF802C074
Access: Read-write
RSE: Receive Symbol Errors
An 8-bit register counting the number of frames that had rx_er asserted during reception. Receive symbol errors are also
counted as an FCS or alignment error if the frame is between 64 and 1518 bytes in length (1536 if bit 8 is set in the network con-
figuration register). If the frame is larger, it is recorded as a jabber error.
45.6.26.16 Excessive Length Errors Register
Name: EMAC_ELE
Address: 0xF802C078
Access: Read-write
EXL: Excessive Length Errors
An 8-bit register counting the number of frames received exceeding 1518 bytes (1536 if bit 8 set in network configuration register)
in length but do not have either a CRC error, an alignment error nor a receive symbol error.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
RSE
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
EXL