Datasheet

1127
SAM9G15 [DATASHEET]
11052D–ATARM–31-Oct-12
45.9 PLL Characteristics
The following configuration of ICPLLA and OUTA must be done for each PLLA frequency range.
45.9.1 UTMI PLL Characteristics
Table 45-15. PLLA Characteristics
Symbol Parameter Conditions Min Typ Max Unit
F
OUT
Output Frequency Refer to following table 400 800 MHz
F
IN
Input Frequency 2 32 MHz
I
PLL
Current Consumption
active mode 7 9 mA
standby mode 1 µA
T Startup Time 50 µs
Table 45-16. PLLA Frequency Regarding ICPLLA and OUTA
PLL Frequency Range (MHz) ICPLLA OUTA
745 - 800 0 0 0
695 - 750 0 0 1
645 - 700 0 1 0
595 - 650 0 1 1
545 - 600 1 0 0
495 - 550 1 0 1
445 - 500 1 1 0
400 - 450 1 1 1
Table 45-17. Phase Lock Loop Characteristics
Symbol Parameter Conditions Min Typ Max Unit
F
IN
Input Frequency 4 12 32 MHz
F
OUT
Output Frequency 450 480 600 MHz
I
PLL
Current Consumption
active mode 5 8 mA
standby mode 1.5 µA
T Startup Time 50 µs