14.4.1 Real-time Timer Mode Register
Register Name: RTT_MR
Access Type: Read-write
RTPRES: Real-time Timer Prescaler Value
Defines the number of SLCK periods required to increment the real-time timer. RTPRES is defined as follows:
RTPRES = 0: The Prescaler Period is equal to 2
16
RTPRES 0: The Prescaler Period is equal to RTPRES.
ALMIEN: Alarm Interrupt Enable
0 = The bit ALMS in RTT_SR has no effect on interrupt.
1 = The bit ALMS in RTT_SR asserts interrupt.
RTTINCIEN: Real-time Timer Increment Interrupt Enable
0 = The bit RTTINC in RTT_SR has no effect on interrupt.
1 = The bit RTTINC in RTT_SR asserts interrupt.
RTTRST: Real-time Timer Restart
1 = Reloads and restarts the clock divider with the new programmed value. This also resets the 32-bit counter.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
–––––RTTRSTRTTINCIENALMIEN
15 14 13 12 11 10 9 8
RTPRES
76543210
RTPRES