Datasheet

579
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
37.5.26.17Receive Jabbers Register
Register Name: EMAC_RJA
Access Type: Read-write
RJB: Receive Jabbers
An 8-bit register counting the number of frames received exceeding 1518 bytes (1536 if bit 8 set in network configuration register)
in length and have either a CRC error, an alignment error or a receive symbol error.
37.5.26.18Undersize Frames Register
Register Name: EMAC_USF
Access Type: Read-write
USF: Undersize Frames
An 8-bit register counting the number of frames received less than 64 bytes in length but do not have either a CRC error, an align-
ment error or a receive symbol error.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
RJB
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
USF