Datasheet

573
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
37.5.26.5 Frames Received OK Register
Register Name: EMAC_FRO
Access Type: Read-write
FROK: Frames Received OK
A 24-bit register counting the number of good frames received, i.e., address recognized and successfully copied to memory. A
good frame is of length 64 to 1518 bytes (1536 if bit 8 set in network configuration register) and has no FCS, alignment or receive
symbol errors.
37.5.26.6 Frames Check Sequence Errors Register
Register Name: EMAC_FCSE
Access Type: Read-write
FCSE: Frame Check Sequence Errors
An 8-bit register counting frames that are an integral number of bytes, have bad CRC and are between 64 and 1518 bytes in
length (1536 if bit 8 set in network configuration register). This register is also incremented if a symbol error is detected and the
frame is of valid length and has an integral number of bytes.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
FROK
15 14 13 12 11 10 9 8
FROK
76543210
FROK
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
FCSE