Datasheet
571
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
37.5.26 EMAC Statistic Registers
These registers reset to zero on a read and stick at all ones when they count to their maximum value. They should be read fre-
quently enough to prevent loss of data. The receive statistics registers are only incremented when the receive enable bit is set in
the network control register. To write to these registers, bit 7 must be set in the network control register. The statistics register
block contains the following registers.
37.5.26.1 Pause Frames Received Register
Register Name: EMAC_PFR
Access Type: Read-write
• FROK: Pause Frames Received OK
A 16-bit register counting the number of good pause frames received. A good frame has a length of 64 to 1518 (1536 if bit 8 set in
network configuration register) and has no FCS, alignment or receive symbol errors.
37.5.26.2 Frames Transmitted OK Register
Register Name: EMAC_FTO
Access Type: Read-write
• FTOK: Frames Transmitted OK
A 24-bit register counting the number of frames successfully transmitted, i.e., no underrun and not too many retries.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
FROK
76543210
FROK
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
FTOK
15 14 13 12 11 10 9 8
FTOK
76543210
FTOK