Datasheet

558
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
37.5.8 Interrupt Status Register
Register Name: EMAC_ISR
Access Type: Read-write
MFD: Management Frame Done
The PHY maintenance register has completed its operation. Cleared on read.
RCOMP: Receive Complete
A frame has been stored in memory. Cleared on read.
RXUBR: Receive Used Bit Read
Set when a receive buffer descriptor is read with its used bit set. Cleared on read.
TXUBR: Transmit Used Bit Read
Set when a transmit buffer descriptor is read with its used bit set. Cleared on read.
TUND: Ethernet Transmit Buffer Underrun
The transmit DMA did not fetch frame data in time for it to be transmitted or hresp returned not OK. Also set if a used bit is read
mid-frame or when a new transmit queue pointer is written. Cleared on read.
RLE: Retry Limit Exceeded
Cleared on read.
TXERR: Transmit Error
Transmit buffers exhausted in mid-frame - transmit error. Cleared on read.
TCOMP: Transmit Complete
Set when a frame has been transmitted. Cleared on read.
ROVR: Receive Overrun
Set when the receive overrun status bit gets set. Cleared on read.
HRESP: Hresp not OK
Set when the DMA block sees a bus error. Cleared on read.
PFR: Pause Frame Received
Indicates a valid pause has been received. Cleared on a read.
PTZ: Pause Time Zero
Set when the pause time register, 0x38 decrements to zero. Cleared on a read.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
PTZ PFR HRESP ROVR
76543210
TCOMP TXERR RLE TUND TXUBR RXUBR RCOMP MFD