Datasheet

551
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
37.5.2 Network Configuration Register
Register Name: EMAC_NCFGR
Access Type: Read-write
SPD: Speed
Set to 1 to indicate 100 Mbit/s operation, 0 for 10 Mbit/s.
FD: Full Duplex
If set to 1, the transmit block ignores the state of collision and carrier sense and allows receive while transmitting.
CAF: Copy All Frames
When set to 1, all valid frames are received.
JFRAME: Jumbo Frames
Set to one to enable jumbo frames of up to 10240 bytes to be accepted.
NBC: No Broadcast
When set to 1, frames addressed to the broadcast address of all ones are not received.
MTI: Multicast Hash Enable
When set, multicast frames are received when the 6-bit hash function of the destination address points to a bit that is set in the
hash register.
UNI: Unicast Hash Enable
When set, unicast frames are received when the 6-bit hash function of the destination address points to a bit that is set in the hash
register.
BIG: Receive 1536 bytes frames
Setting this bit means the EMAC receives frames up to 1536 bytes in length. Normally, the EMAC would reject any frame above
1518 bytes.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––IRXFCSEFRHDDRFCSRLCE
15 14 13 12 11 10 9 8
RBOF PAE RTY CLK BIG
76543210
UNI MTI NBC CAF JFRAME FD SPD