Datasheet
513
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
36.8.4 CAN Interrupt Mask Register
Name: CAN_IMR
Access Type: Read-only
• MBx: Mailbox x Interrupt Mask
0 = Mailbox x interrupt is disabled.
1 = Mailbox x interrupt is enabled.
• ERRA: Error Active Mode Interrupt Mask
0 = ERRA interrupt is disabled.
1 = ERRA interrupt is enabled.
• WARN: Warning Limit Interrupt Mask
0 = Warning Limit interrupt is disabled.
1 = Warning Limit interrupt is enabled.
• ERRP: Error Passive Mode Interrupt Mask
0 = ERRP interrupt is disabled.
1 = ERRP interrupt is enabled.
• BOFF: Bus Off Mode Interrupt Mask
0 = BOFF interrupt is disabled.
1 = BOFF interrupt is enabled.
• SLEEP: Sleep Interrupt Mask
0 = SLEEP interrupt is disabled.
1 = SLEEP interrupt is enabled.
• WAKEUP: Wakeup Interrupt Mask
0 = WAKEUP interrupt is disabled.
1 = WAKEUP interrupt is enabled.
• TOVF: Timer Overflow Interrupt Mask
0 = TOVF interrupt is disabled.
1 = TOVF interrupt is enabled.
31 30 29 28 27 26 25 24
– – – BERR FERR AERR SERR CERR
23 22 21 20 19 18 17 16
TSTP TOVF WAKEUP SLEEP BOFF ERRP WARN ERRA
15 14 13 12 11 10 9 8
––––––––
76543210
MB7MB6MB5MB4MB3MB2MB1MB0