Datasheet
478
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
35.6.9 ADC Interrupt Disable Register
Register Name: ADC_IDR
Access Type: Write-only
• EOCx: End of Conversion Interrupt Disable x
• OVREx: Overrun Error Interrupt Disable x
• DRDY: Data Ready Interrupt Disable
• GOVRE: General Overrun Error Interrupt Disable
• ENDRX: End of Receive Buffer Interrupt Disable
• RXBUFF: Receive Buffer Full Interrupt Disable
0 = No effect.
1 = Disables the corresponding interrupt.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––RXBUFFENDRXGOVREDRDY
15 14 13 12 11 10 9 8
OVRE7 OVRE6 OVRE5 OVRE4 OVRE3 OVRE2 OVRE1 OVRE0
76543210
EOC7 EOC6 EOC5 EOC4 EOC3 EOC2 EOC1 EOC0