35.6.7 ADC Last Converted Data Register
Register Name: ADC_LCDR
Access Type: Read-only
• LDATA: Last Data Converted
The analog-to-digital conversion data is placed into this register at the end of a conversion and remains until a new conversion is
completed.
35.6.8 ADC Interrupt Enable Register
Register Name: ADC_IER
Access Type: Write-only
• EOCx: End of Conversion Interrupt Enable x
• OVREx: Overrun Error Interrupt Enable x
• DRDY: Data Ready Interrupt Enable
• GOVRE: General Overrun Error Interrupt Enable
• ENDRX: End of Receive Buffer Interrupt Enable
• RXBUFF: Receive Buffer Full Interrupt Enable
0 = No effect.
1 = Enables the corresponding interrupt.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
–––––– LDATA
76543210
LDATA
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––RXBUFFENDRXGOVREDRDY
15 14 13 12 11 10 9 8
OVRE7 OVRE6 OVRE5 OVRE4 OVRE3 OVRE2 OVRE1 OVRE0
76543210
EOC7 EOC6 EOC5 EOC4 EOC3 EOC2 EOC1 EOC0