35.6.2 ADC Mode Register
Register Name: ADC_MR
Access Type: Read/Write
TRGEN: Trigger Enable
TRGSEL: Trigger Selection
LOWRES: Resolution
SLEEP: Sleep Mode
31 30 29 28 27 26 25 24
–––– SHTIM
23 22 21 20 19 18 17 16
–STARTUP
15 14 13 12 11 10 9 8
PRESCAL
76543210
SLEEP LOWRES TRGSEL TRGEN
TRGEN Selected TRGEN
0 Hardware triggers are disabled. Starting a conversion is only possible by software.
1 Hardware trigger selected by TRGSEL field is enabled.
TRGSEL Selected TRGSEL
000TIOA Ouput of the Timer Counter Channel 0
001TIOA Ouput of the Timer Counter Channel 1
010TIOA Ouput of the Timer Counter Channel 2
011Reserved
100Reserved
101Reserved
110External trigger
111Reserved
LOWRES Selected Resolution
0 10-bit resolution
1 8-bit resolution
SLEEP Selected Mode
0 Normal Mode
1 Sleep Mode