Datasheet
447
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
34.6.1 UDP Frame Number Register
Register Name: UDP_ FRM_NUM
Access Type: Read-only
• FRM_NUM[10:0]: Frame Number as Defined in the Packet Field Formats
This 11-bit value is incremented by the host on a per frame basis. This value is updated at each start of frame.
Value Updated at the SOF_EOP (Start of Frame End of Packet).
• FRM_ERR: Frame Error
This bit is set at SOF_EOP when the SOF packet is received containing an error.
This bit is reset upon receipt of SOF_PID.
• FRM_OK: Frame OK
This bit is set at SOF_EOP when the SOF packet is received without any error.
This bit is reset upon receipt of SOF_PID (Packet Identification).
In the Interrupt Status Register, the SOF interrupt is updated upon receiving SOF_PID. This bit is set without waiting for EOP.
Note: In the 8-bit Register Interface, FRM_OK is bit 4 of FRM_NUM_H and FRM_ERR is bit 3 of FRM_NUM_L.
31 30 29 28 27 26 25 24
--- --- --- --- --- --- --- ---
23 22 21 20 19 18 17 16
––––––FRM_OKFRM_ERR
15 14 13 12 11 10 9 8
––––– FRM_NUM
76543210
FRM_NUM