33.6.12 PWM Channel Counter Register
Register Name: PWM_CCNT[0..X-1]
Access Type: Read-only
CNT: Channel Counter Register
Internal counter value. This register is reset when:
the channel is enabled (writing CHIDx in the PWM_ENA register).
the counter reaches CPRD value defined in the PWM_CPRDx register if the waveform is left aligned.
31 30 29 28 27 26 25 24
CNT
23 22 21 20 19 18 17 16
CNT
15 14 13 12 11 10 9 8
CNT
76543210
CNT