Datasheet

372
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
31.8.16 SSC Interrupt Mask Register
Name: SSC_IMR
Access Type: Read-only
TXRDY: Transmit Ready Interrupt Mask
0: The Transmit Ready Interrupt is disabled.
1: The Transmit Ready Interrupt is enabled.
TXEMPTY: Transmit Empty Interrupt Mask
0: The Transmit Empty Interrupt is disabled.
1: The Transmit Empty Interrupt is enabled.
ENDTX: End of Transmission Interrupt Mask
0: The End of Transmission Interrupt is disabled.
1: The End of Transmission Interrupt is enabled.
TXBUFE: Transmit Buffer Empty Interrupt Mask
0: The Transmit Buffer Empty Interrupt is disabled.
1: The Transmit Buffer Empty Interrupt is enabled.
RXRDY: Receive Ready Interrupt Mask
0: The Receive Ready Interrupt is disabled.
1: The Receive Ready Interrupt is enabled.
OVRUN: Receive Overrun Interrupt Mask
0: The Receive Overrun Interrupt is disabled.
1: The Receive Overrun Interrupt is enabled.
ENDRX: End of Reception Interrupt Mask
0: The End of Reception Interrupt is disabled.
1: The End of Reception Interrupt is enabled.
RXBUFF: Receive Buffer Full Interrupt Mask
0: The Receive Buffer Full Interrupt is disabled.
1: The Receive Buffer Full Interrupt is enabled.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––RXSYNTXSYN CP1 CP0
76543210
RXBUFF ENDRX OVRUN RXRDY TXBUFE ENDTX TXEMPTY TXRDY