31.8.13 SSC Status Register
Name: SSC_SR
Access Type: Read-only
• TXRDY: Transmit Ready
0: Data has been loaded in SSC_THR and is waiting to be loaded in the Transmit Shift Register (TSR).
1: SSC_THR is empty.
• TXEMPTY: Transmit Empty
0: Data remains in SSC_THR or is currently transmitted from TSR.
1: Last data written in SSC_THR has been loaded in TSR and last data loaded in TSR has been transmitted.
• ENDTX: End of Transmission
0: The register SSC_TCR has not reached 0 since the last write in SSC_TCR or SSC_TNCR.
1: The register SSC_TCR has reached 0 since the last write in SSC_TCR or SSC_TNCR.
• TXBUFE: Transmit Buffer Empty
0: SSC_TCR or SSC_TNCR have a value other than 0.
1: Both SSC_TCR and SSC_TNCR have a value of 0.
• RXRDY: Receive Ready
0: SSC_RHR is empty.
1: Data has been received and loaded in SSC_RHR.
• OVRUN: Receive Overrun
0: No data has been loaded in SSC_RHR while previous data has not been read since the last read of the Status Register.
1: Data has been loaded in SSC_RHR while previous data has not yet been read since the last read of the Status Register.
• ENDRX: End of Reception
0: Data is written on the Receive Counter Register or Receive Next Counter Register.
1: End of PDC transfer when Receive Counter Register has arrived at zero.
• RXBUFF: Receive Buffer Full
0: SSC_RCR or SSC_RNCR have a value other than 0.
1: Both SSC_RCR and SSC_RNCR have a value of 0.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––RXENTXEN
15 14 13 12 11 10 9 8
––––RXSYNTXSYN CP1 CP0
76543210
RXBUFF ENDRX OVRUN RXRDY TXBUFE ENDTX TXEMPTY TXRDY