Datasheet
352
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
31.8.1 SSC Control Register
Name: SSC_CR
Access Type: Write-only
• RXEN: Receive Enable
0: No effect.
1: Enables Receive if RXDIS is not set.
• RXDIS: Receive Disable
0: No effect.
1: Disables Receive. If a character is currently being received, disables at end of current character reception.
• TXEN: Transmit Enable
0: No effect.
1: Enables Transmit if TXDIS is not set.
• TXDIS: Transmit Disable
0: No effect.
1: Disables Transmit. If a character is currently being transmitted, disables at end of current character transmission.
• SWRST: Software Reset
0: No effect.
1: Performs a software reset. Has priority on any other bit in SSC_CR.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
SWRST–––––TXDISTXEN
76543210
––––––RXDISRXEN