Datasheet

335
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
30.7.12 USART FI DI RATIO Register
Name: US_FIDI
Access Type: Read-write
Reset Value : 0x174
FI_DI_RATIO: FI Over DI Ratio Value
0: If ISO7816 mode is selected, the Baud Rate Generator generates no signal.
1 - 2047: If ISO7816 mode is selected, the Baud Rate is the clock provided on SCK divided by FI_DI_RATIO.
30.7.13 USART Number of Errors Register
Name: US_NER
Access Type: Read-only
NB_ERRORS: Number of Errors
Total number of errors that occurred during an ISO7816 transfer. This register automatically clears when read.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––– FI_DI_RATIO
76543210
FI_DI_RATIO
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
NB_ERRORS