Datasheet

205
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
26.5.1 Debug Unit Control Register
Name: DBGU_CR
Access Type: Write-only
RSTRX: Reset Receiver
0 = No effect.
1 = The receiver logic is reset and disabled. If a character is being received, the reception is aborted.
RSTTX: Reset Transmitter
0 = No effect.
1 = The transmitter logic is reset and disabled. If a character is being transmitted, the transmission is aborted.
RXEN: Receiver Enable
0 = No effect.
1 = The receiver is enabled if RXDIS is 0.
RXDIS: Receiver Disable
0 = No effect.
1 = The receiver is disabled. If a character is being processed and RSTRX is not set, the character is completed before the
receiver is stopped.
TXEN: Transmitter Enable
0 = No effect.
1 = The transmitter is enabled if TXDIS is 0.
TXDIS: Transmitter Disable
0 = No effect.
1 = The transmitter is disabled. If a character is being processed and a character has been written the DBGU_THR and RSTTX is
not set, both characters are completed before the transmitter is stopped.
RSTSTA: Reset Status Bits
0 = No effect.
1 = Resets the status bits PARE, FRAME and OVRE in the DBGU_SR.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
–––––––
RSTSTA
76543210
TXDIS TXEN RXDIS RXEN RSTTX RSTRX
––