Datasheet
187
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
25.9.8 PMC Clock Generator Main Clock Frequency Register
Register Name: CKGR_MCFR
Access Type: Read-only
• MAINF: Main Clock Frequency
Gives the number of Main Clock cycles within 16 Slow Clock periods.
• MAINRDY: Main Clock Ready
0 = MAINF value is not valid or the Main Oscillator is disabled.
1 = The Main Oscillator has been enabled previously and MAINF value is available.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
–––––––MAINRDY
15 14 13 12 11 10 9 8
MAINF
76543210
MAINF