Datasheet
133
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
21.5 Hardware and Software Constraints
SAM-BA boot copies itself in the SRAM and uses a block of internal SRAM for variables and stacks. The
remaining available size for the user code is 122880 bytes for SAM7x512, 57344 bytes for SAM7X256 and 24576
bytes for SAM7X128.
USB requirements:
pull-up on DDP
18.432 MHz Quartz
Table 21-4. User Area Addresses
Device Start Address End Address Size (bytes)
SAM7X512 0x202000 0x220000 122880
SAM7X256 0x202000 0x210000 57344
SAM7X128 0x202000 0x208000 24576
Table 21-5. Pins Driven during Boot Program Execution
Peripheral Pin PIO Line
DBGU DRXD PA27
DBGU DTXD PA28