Datasheet
132
SAM7X Series [DATASHEET]
6120K–ATARM–11-Feb-14
The device also handles some class requests defined in the CDC class.
Unhandled requests are STALLed.
21.4.3.2 Communication Endpoints
There are two communication endpoints and endpoint 0 is used for the enumeration process. Endpoint 1 is a 64-byte
Bulk OUT endpoint and endpoint 2 is a 64-byte Bulk IN endpoint. SAM-BA Boot commands are sent by the host through
the endpoint 1. If required, the message is split by the host into several data payloads by the host driver.
If the command requires a response, the host can send IN transactions to pick up the response.
Table 21-3. Handled Class Requests
Request Definition
SET_LINE_CODING
Configures DTE rate, stop bits, parity and number of
character bits.
GET_LINE_CODING
Requests current DTE rate, stop bits, parity and number of
character bits.
SET_CONTROL_LINE_STATE
RS-232 signal used to tell the DCE device the DTE device
is now present.