Datasheet

Table Of Contents
371
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
Figure 31-10. Asynchronous Start Detection
Figure 31-11. Asynchronous Character Reception
31.6.3.3 Synchronous Receiver
In synchronous mode (SYNC = 1), the receiver samples the RXD signal on each rising edge of the Baud Rate
Clock. If a low level is detected, it is considered as a start. All data bits, the parity bit and the stop bits are sampled
and the receiver waits for the next start bit. Synchronous mode operations provide a high speed transfer capability.
Configuration fields and bits are the same as in asynchronous mode.
Figure 31-12 illustrates a character reception in synchronous mode.
Figure 31-12. Synchronous Mode Character Reception
Sampling
Clock (x16)
RXD
Start
Detection
Sampling
Baud Rate
Clock
RXD
Start
Rejection
Sampling
12345678
123456701234
123456789 10111213141516
D0
Sampling
D0
D1
D2
D3
D4
D5 D6 D7
RXD
Parity
Bit
Stop
Bit
Example: 8-bit, Parity Enabled
Baud Rate
Clock
Start
Detection
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
16
samples
D0 D1 D2 D3 D4 D5 D6 D7
RXD
Start
Sampling
Parity Bit
Stop Bit
Example: 8-bit, Parity Enabled 1 Stop
Baud Rate
Clock