Figure 30-17. TWI Read Operation with Single Data Byte without Internal Address
Set the Control register:
- Master enable
TWI_CR = MSEN + SVDIS
Set the Master Mode register:
- Device slave address
- Internal address size (IADRSZ)
- Transfer direction bit
Read ==> bit MREAD = 1
Read Status register
BEGIN
Set TWI clock
(CLDIV, CHDIV, CKDIV) in TWI_CWGR
(Needed only once)
Ye s
Set the internal address
TWI_IADR = address
Start the transfer
TWI_CR = START | STOP
Read Status register
RXRDY = 1?
Read Receive Holding register
No