Datasheet

Table Of Contents
296
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
29.3 Block Diagram
Figure 29-1. Block Diagram
29.4 Application Block Diagram
Figure 29-2. Application Block Diagram
29.4.1 I/O Lines Description
29.5 Product Dependencies
29.5.1 I/O Lines
Both TWD and TWCK are bidirectional lines, connected to a positive supply voltage via a current
source or pull-up resistor (see Figure 29-2 on page 296). When the bus is free, both lines are
APB Bridge
PMC
MCK
Two-wire
Interface
PIO
AIC
TWI
Interrupt
TWCK
TWD
Host with
TWI
Interface
TWD
TWCK
Atmel TWI
Serial EEPROM
I²C RTC
I²C LCD
Controller
Slave 1 Slave 2 Slave 3
VDD
I²C Temp.
Sensor
Slave 4
Rp: Pull up value as given by the I²C Standard
Rp Rp
Table 29-3. I/O Lines Description
Pin Name Pin Description Type
TWD Two-wire Serial Data Input/Output
TWCK Two-wire Serial Clock Input/Output