21.6 Hardware and Software Constraints
SAM-BA boot copies itself in the SRAM and uses a block of internal SRAM for variables and stacks. The
remaining available sizes for the user codes are as follows: 57344 bytes for SAM7S512, 57344 bytes for
SAM7S256, 24576 bytes for SAM7S128, 8192 bytes for SAM7S64, 2048 bytes for SAM7S321 and SAM7S32,
3840 bytes for SAM7S161 and SAM7S16.
USB requirements: (Does not pertain to SAM7S32/16)
18.432 MHz Quartz
PIOA16 dedicated to the USB Pull-up
Table 21-4. User Area Addresses
Device Start Address End Address Size (bytes)
SAM7S512 0x202000 0x210000 57344
SAM7S256 0x202000 0x210000 57344
SAM7S128 0x202000 0x208000 24576
SAM7S64 0x202000 0x204000 8192
SAM7S321 0x202000 0x210000 2048
SAM7S32 0x201400 0x201C00 2048
SAM7S161 0x200000 0200F00 3840
SAM7S16 0x200000 0200F00 3840
Table 21-5. Pins Driven during Boot Program Execution
Peripheral Pin PIO Line
DBGU DRXD PA9
DBGU DTXD PA10